78
Message Format:
BYTE command (ASCII ‘C’, 43H)
BYTE seqno
BYTE Radio Channel (1 to 15)
Set Network Subchannel
Purpose: To set the subchannel of the Serial Adapter’s network
protocol.
Response Expected from Serial Adapter: “Subchannel Confirma-
tion”
Message Format:
BYTE command (ASCII ‘S’, 53H)
BYTE seqno
BYTE subchannel (1 to 15)
Set Baud Rate
Purpose: To set the baud rate of the Serial Adapter serial line.
When the command is received, the Serial Adapter generates the
Baud Rate Confirmation message. After that, it then switches to
the new baud rate.
Response Expected from Serial Adapter: “Baud Rate Confirma-
tion”
Message Format:
BYTE command (ASCII ‘B’, 42H)
BYTE seqno
BYTE baudrate (HEX 02 through 0A)
Seitenansicht 83